IBM today introduced “Cool Blue,” a technology component that can use the existing chilled water supply for air conditioning systems already located in the majority of customer datacenters to reduce server heat emissions by up to 55 percent. IBM is the first systems vendor to develop such a technology. “Cool Blue” can be deployed on any server, enabling customers to ease the burden on existing air conditioning units and potentially lower energy costs by up to 15 percent. Inside the door of the Heat eXchanger, sealed tubes filled with circulating chilled water effectively remove up to 55 percent of the heat generated in a fully populated rack and dissipate it so it is not released into the datacenter. In fact, the Heat eXchanger can remove up to 50,000 BTU of heat generated by a full server rack, based on total rack output. The IBM eServer Heat eXchanger is generally available today, with pricing starting at $ 4,299 in the United States.

IBM today introduced "Cool Blue," a technology component that can use the
existing chilled water supply for air conditioning systems already located in
the majority of customer datacenters to reduce server heat emissions by up to 55
percent. IBM is the first systems vendor to develop such a technology. "Cool
Blue" can be deployed on any server, enabling customers to ease the burden on
existing air conditioning units and potentially lower energy costs by up to 15
percent. It is available immediately.

Designed to easily fit on to the IBM eServer Enterprise rack, "Cool Blue," or
the IBM eServerTM Rear Door Heat eXchangerTM as it is officially termed, is
designed to help customers whose datacenters have reached the limits of cooling
capacity, but still have space to add racks of systems. The improved cooling
from the Heat eXchanger enables customers to fully populate individual racks,
freeing valuable floor space without the need to purchase additional air
conditioning units. The Heat eXchanger can also alleviate the issues caused by
other vendors’ servers in the datacenter where the customer might have cooling
challenges.

"IBM has been addressing the cooling needs of customer datacenters for years and
the new ‘Cool Blue’ technology is a giant leap forward in overcoming previously
insurmountable air conditioning limitations," said Rod Adkins, vice president of
development, IBM Systems and Technology Group. "As customers try to incorporate
more processing power into the same datacenter footprint, this breakthrough
technology will help them win the war on heat."

HypoVereinsbank, the second largest bank in Germany, selected the Heat eXchanger
to reduce heat temperature in their High Performance Computing environment.

"The Heat eXchanger is a very unique solution. It finally allowed us to get the
density we’ve been aiming for, without increasing our cooling requirements or
costs," said Volker Machmeier, technical director for HVBInfo. "In addition, the
door is extremely easy to install and use. It fit right in to our existing
infrastructure to quickly provide more cooling capacity to areas where it was
most needed."

Inside the door of the Heat eXchanger, sealed tubes filled with circulating
chilled water effectively remove up to 55 percent of the heat generated in a
fully populated rack and dissipate it so it is not released into the datacenter.
In fact, the Heat eXchanger can remove up to 50,000 BTU of heat generated by a
full server rack, based on total rack output.

The updated IBM eServer Cluster 1350 system will be one of the first eServer
technologies to deliver support for the Heat eXchanger. Leveraging this new
technology, the Cluster 1350 will enable high performance customers to conquer
thermal challenges in high-density IT environments and better utilize existing
facilities.

IBM is the recognized leader in cooling technology and its rack servers are
engineered with the cooling and efficiency needs of customers in mind. IBM
breakthroughs in server cooling technology include features like Calibrated
Vectored Cooling, the industry’s most advanced systems-power and cooling
architecture, which intelligently engineers the path of cool air flow through
IBM server systems.

The Heat eXchanger can be easily installed by customers and moved to different
racks to address changing cooling requirements. Its unique design uses standard
fittings and couplings and, because there are no moving or electrical parts,
helps increase reliability. It can be opened like any rear cover, so
serviceability of racks fitted with a Heat eXchanger is as easy as a standard
air cooled rack.

Pricing and availability

The IBM eServer Heat eXchanger is generally available today, with pricing
starting at $ 4,299 in the United States. The Heat eXchanger is also available as
part of the Cluster 1350, with prices varying per the configuration of the
cluster.